page-banner

product

Discount Femur And Tibia Quotes – Femur Intramedullary Nail System – AND

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

It adheres on the tenet "Honest, industrious, enterprising, innovative" to acquire new solutions continuously. It regards prospects, success as its personal success. Let us build prosperous future hand in hand for Patellofemoral Joint Replacement, Cervical And Thoracic Spine, Open Bone Fractures, We are willing to give you the lowest price in the market, best quality and very nice sales service.Welcome to do bussines with us,let's be double win.
Discount Femur And Tibia Quotes – Femur Intramedullary Nail System – AND Detail:

Diameter(mm) Length(mm)
9 170 200 240(L&R)
10
11
12
Diameter(mm) Length(mm)(L&R)
9 320 340 360 380 400 420
10
11
12

γ-II Interlocking Intramedullary Nail
The medical-lateral angle of 5° allows the insertion at tip of the greater trochanter (the proximal diameter is 16.0mm).
Lateral flattening design eases the insertion and reduces the stress ti the lateral cortical bone.
130 collodiaphysial angle(CCD).
The elastic groove tip design.
Ease the insertion.
Reduce the stress concentration.
Distal curved design prevents the nail tip against to the cortical bone.
Reduce the insertion resistance and pain incidence rate.

Lag screw

The lag screw insertion can provide excellent compaction to cancellous bone.

The tip wide surface provides better anchoring.

Especially for osteoporotic patients.

Anti-rotational and stability achieved by one single element.

Pure Tianium PFNA Implants

Locking bolt

Double thread design to reduce the operation time

Pure Tianium PFNA Implants

End cap

0/5/10/15mm length With the suitable length to take it out

Pure Tianium PFNA Implants

Case

Pure-Tianium-PFNA-Implants-case01
Pure-Tianium-PFNA-Implants-case2
Pure-Tianium-PFNA-Implants-case3

Instruments

Pure Tianium PFNA Implants instruments1
Pure Tianium PFNA Implants instruments2
Pure Tianium PFNA Implants instruments3
Pure Tianium PFNA Implants instruments4

Medical Tips

Intertrochanteric fracture
Intertrochanteric fracture (INTERTROCHANTERIC FRACTURE), also known as intertrochanteric fracture.

It is characterized by frequently-occurring elderly people, mostly low-energy injuries caused by osteoporosis in the elderly, and with the trend of aging population, the incidence rate is increasing year by year.

For intertrochanteric fractures, the most commonly used internal fixation materials include intramedullary and extramedullary fixation. Among them, intramedullary fixation is due to.

The surgical incision is small, the bleeding is small, and the operation time is short. It conforms to the principle of minimally invasive. At the same time, intramedullary fixation is more conducive to the conduction of load and avoids extramedullary
The potential fracture risk of uneven screw stress load caused by eccentric fixation is more widely used in clinical practice. More often in intramedullary fixation.

Intertan, Gamma nail, PFN, PFNA (proximal femoral nail antirotation) are used.

In the fixed structure, the main nail of the medullary nail is too thin or the holding force of the head and neck nail is insufficient, the surgical technique apex distance (TAD) does not meet the requirements, the fracture type is extremely unstable, especially the proximal femur lacks effective support, and the rehabilitation is prematurely loaded. When one of the above conditions exists, there is micro-movement between the internal plant and the bone before the fracture is healed. The combined structure of the femoral reconstruction intramedullary nail is similar to the “mechanical connecting rod”, and the connecting rod has a tendency to “rotate” due to eccentric force. The “rotation” trend will cause the two head and neck studs to move in the opposite direction, and the result is the “Z effect” or “reverse Z effect.


Product detail pictures:

Discount Femur And Tibia Quotes –  Femur Intramedullary Nail System – AND detail pictures

Discount Femur And Tibia Quotes –  Femur Intramedullary Nail System – AND detail pictures

Discount Femur And Tibia Quotes –  Femur Intramedullary Nail System – AND detail pictures


Related Product Guide:

Our firm aims to operating faithfully, serving to all of our consumers , and working in new technology and new machine continually for Discount Femur And Tibia Quotes – Femur Intramedullary Nail System – AND , The product will supply to all over the world, such as: Czech republic, Rwanda, Kuala Lumpur, We are seeking the chances to meet all the friends from both at home and abroad for the win-win cooperation. We sincerely hope to have long-term cooperation with all of you on the bases of mutual benefit and common development.
  • The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Dolores from Slovenia - 2017.02.14 13:19
    This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Bruno Cabrera from Greece - 2018.12.05 13:53
    Write your message here and send it to us