CE Certification T4 Spinal Cord Injury Quotes – Kyphoplasty Tools System with various combination – AND
CE Certification T4 Spinal Cord Injury Quotes – Kyphoplasty Tools System with various combination – AND Detail:
Products Advantages
Easy operations for doctors, to shorten operation time.
Specially designed according to the anatomical characteristics of the thoracic vertebra.
Ergonomic design.
Safe, simple and easy to use.
Item Description
Percutaneous Access Device
Integrated, one-step design for quick and efficient percutaneous access to bone and create bone tissue guide channel.
Reduce the trauma effectively.
Available bevel or diamond tips to let doctors choose according to clinical needs.
Expansion cannula
Conical tip design cut cleanly, go through cancellous bone easily and fit for biopsy
Aiguille
Special material and precise grinding to meet clinical needs
Bone Cement Applier
Smaller-diameter design and precise process for ideal feeding
Standard-interface design for reliable connection to reduce operation risk
Volum: 1.5ml/pc.
Balloon Inflation Pump
Control pressure accurately, Stable performance, Easy to operate, Non-latex
Kyphoplasty balloon
Guide Wire
Case
Medical Tips
Percutaneous Vertebroplasty (PVP)
It started in France in 1987 and was used to treat vertebral tumors in the United States in 1997, followed by extension treatment of osteoporotic compression fractures.
Method: Under the guidance of C-arm or CT, a special trocar was inserted percutaneously through the pedicle to the front edge of the midline of the compressed fracture vertebral body, and bone cement was injected under pressure.
Advantages: It can increase the stability of the vertebral body and relieve pain.
Insufficiency: unable to correct the compressed spine, Potential leakage of bone cement can cause nerve damage and spinal stenosis.
Percutaneous Kyphoplasty (PKP)
Based on the Vertebroplasty, this method first uses a special balloon to reduce the compressed vertebral body, and then injects bone cement under low pressure, which can reduce the risk of leakage and has a better effect.
Advantages: safer than PVP, not only enhances stability, relieves pain, but also Restore vertebral height and physiological function.
Insufficiency: Inflated airbags may also further damage the vertebral body and adjacent tissues.
Indications and Contraindications
The indications for kyphoplasty include recent vertebral compression fractures due to osteoporosis, myeloma, metastasis and vertebral angioma with intractable pain and with no neurological symptoms. The main contraindications are coagulation disorders, unstable fractures or complete vertebral collapse (vertebra plana).
Product detail pictures:
Related Product Guide:
We have been ready to share our knowledge of advertising worldwide and recommend you suitable products at most aggressive costs. So Profi Tools present you ideal price of money and we've been ready to create with each other with CE Certification T4 Spinal Cord Injury Quotes – Kyphoplasty Tools System with various combination – AND , The product will supply to all over the world, such as: Montpellier, Madrid, Kuwait, To win customers' confidence, Best Source has set up a strong sales and after-sales team to deliver the best product and service. Best Source abides by the idea of "Grow with customer" and philosophy of "Customer-oriented" to achieve cooperation of mutual trust and benefit. Best Source will always stand ready to cooperate with you. Let's grow together!